Test
Accessory for the Enviro-Genie 6-in-1 and Roto-Shake Genie 6-in-1, two stainless steel trays & 24 magnetic mounting bag strips.
Pre-treated, pre-weighed, and disposable for your convenienceThis product complies with the following methods: SM 2540, ASTM D5907, BS EN 15216:2007Save time — cools faster, requires fewer drying and weighing cyclesDisposable to eliminate cross-contaminationThese weighing vessels reduce preparation time, perfect for busy labs analyzing a lot of samples. Each vessel complies with the following methods: SM 2540, ASTM D5907, BS EN 15216:2007. Each vessel is treated to conform with ASTM D5907 Standard Test Methods for Filterable Matter (Total Dissolved Solids) and Nonfilterable Matter (Total Suspended Solids) in Water, then individually printed with the final weight. The material is lightweight, inert to water or wastewater components, and heat resistant. Vessels cool quickly decreasing wait times between heating and weighing.
UniFit with 2.0mm OD x 0.86mm ID x 480mm long tube (PKT 3). Replacement pack of 3 spray chamber drain lines. Typically used with IsoMist XR spray chambers.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
IsoMist XS Kit Thermo PRO. Compatible with Thermo PRO ICP-OES. This IsoMist XS is programmable and temperature-controlled, with a glass cyclonic spray chamber now featuring an improved thermodynamic design that provides an extended temperature range of -25°C to +80°C. The temperature is settable in 1°C increments and can maintain accuracy of + or – 0.1°C. Proven performance results are, improved long-term stability and precision, no dilution for volatile organic solvents, reduced oxide interferences (ICP-MS), enhanced sensitivity and accuracy, lower detection limits, faster washout, and reduced hazardous waste/disposal fees.Replacement parts include 21-809-3186, NC1943061, and 501907304.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Nickel Skimmer Cone, Cold and Hot Plasma (1341420) – Suitable for Thermo Q/RQ/TQ ICP-MS. Specifically designed to operate ONLY with the Cold Plasma Lens Kit (1341380). This skimmer cone can be used with the Cold Plasma Lens Kit to operate in both Cold (RF Power 550 W) and Hot Plasma conditions (RF Power 1550 W). This reduced plasma intensity configuration is typically used to suppress Ar interferences for elements, such as K and Ca; and/or for the analysis of other light elements like Li and Na. Not for samples containing HF. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. Use Skimmer ConeGuard (70-803-1028) to protect cone threads during cleaning. When not in use, keep cones stored in original packaging for protection.For high matrix tolerance and high sensitivity, we recommend NC2046959. For Robust plasma conditions, we recommend TG1045-Ni.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
EzyFit Sample Tube - Twin (PKT 6). A replacement 1.6mm (1/16”) OD and 0.50mm ID capillary with an EzyFit connector on both ends. Typically used with Glass Expansion’s Trident IS Kit P/N NC9281090, 60-808-1185. This fitting connects the mixed sample and internal standard from the mixing T to a Glass Expansion F-Series nebulizer.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Viton Pump Tube 2tag 1.02mm ID White/White (PKT 12).Tag Colors: White/WhiteID mm: 1.02Wall Thickness mm: 0.85OD mm 2.72Overall Length: 175mm (127mm spacing between tags)Number of Tubes Per Pack: 12Physical Properties: Fluoropolymer elastomerSpecial Properties: Special tubing for concentrated acids and corrosive solventsMaterial: Made from Fluran HC F-5500-A or equivalent.Limitations: Limited service lifeGlass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Aluminum Sampler Cone – Aluminum sampler cone for PerkinElmer NexION 1000/2000/300/350 ICP-MS. For lowest nickel background and laser ablation applications. Not recommended for samples containing HF. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection. Use Sampler ConeGuard to protect cone threads during cleaning, 70-803-1024.For standard samples and routine operation, we recommend Nickel Sampler Cones, 501907684. For corrosive samples, including HF, we recommend Platinum Sampler Cones, see catalog number 501907686.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Platinum/Nickel Hyper Skimmer Cone – Platinum and nickel hyper skimmer cone for PerkinElmer NexION 1000/2000/300/350 ICP-MS. Suitable for corrosive samples (e.g., high TDS samples, >5% acid matrix, HF). Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For standard samples and routine operation, we recommend Aluminum Hyper Skimmer Cones, 501907690.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
GazFit Union 8mm (PKT 2). GazFit Union Connector for 8mm OD laser ablation adaptors and 8mm OD rigid walled tubing. Compatible with laser ablation adaptor 21-809-4140.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Nickel Sampler Cone, 100% Nickel (3004661), standard sampler cone made from 100% nickel providing lowest Cu background for Thermo X Series ICP-MS. Suitable for most common applications (e.g., routine aqueous environmental samples, <5% acid matrix, non-HF, non-organic). Use a new Graphite Sampler Cone Gasket (TG5001) each time the cone is re-installed, even if it’s the same cone. Use 10x Magnifier Inspection Tool with Built-In LED Illumination (NC2042261) to inspect cone orifice condition. When not in use, keep cones stored in original packaging for protection.For more efficient heat transfer use Nickel Sampler with Copper Core, 501694614. As acid concentrations begin to exceed 5%, and for samples containing hydrofluoric acid (HF), and other highly corrosive samples, we recommend platinum cones, see TG1026A-Pt/Cu. For lowest Ni background and laser ablation applications see TG1021-Al.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
EzyFit with 1/16 OD X 0.50mm ID x 700mm long sample tube. Package of 10 replacement sample lines compatible with Glass Expansion F-Series Nebulizers. Used to carry sample from peristaltic pump tubing or mixing T to nebulizer. This consumable part should be replaced at a frequency of about every 6 months to ensure optimum sample flow.For EzyFit Connector with 0.75mm ID, 1.3mm OD x 1500mm long sample tube, EZTS-075. For EzyFit Connector with 0.25mm ID, 1.3mm OD x 700mm long sample tube, EZT-025.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
Direct Connect (DC) Nebulizer Gas Fitting Type 61 with Ratchet Connector for Analytic Jena ICP-MS. Contains Ratchet Connector Gas Line 1/4-28 x 750 Assembly (70-803-2001) and ICP Gas Inlet Fitting Type 11/32/61 (70-803-1934). For argon gas connection between DC nebulizer and instrument argon gas supply fitting. Suitable for A61- DC Nebulizers. Compatible with ICP models: Analytic Jena ICP-MS.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
PTFE Sheathed Carbon Fiber Probe 0.25mm ID with EzyFit Connector. Suitable for Cetac ASX-200/500/800 and PerkinElmer S20 Series Autosamplers. EzyFit connector connects probe capillary directly to Glass Expansion F-Series nebulizers.Replacement of autosampler probe is recommended about every 6 months to a year. This will ensure you have unrestricted sample flow. If clogs within probes or nebulizers occur, consider using the Guardian In-Line Sample Filter (P/N NC0897716, 70-803-1108). The Guardian In-Line Sample Filter is spliced into the autosampler probe capillary and can be backflushed using the Eluo Nebulizer Cleaner for Glass Concentric Nebulizers (P/N NC9462559, 70-ELUO), or the Eluo HF Nebulizer Cleaner for OpalMist or DuraMist (P/N 501907353, 70-ELUO-OPD), and Eluo Adaptor for In-Line Filter (P/N NC0801128, 70-803-1160). The Guardian In-Line Sample Filter is reuseable and can last years.Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001
UniFit with 1.3mm OD x 0.75mm ID x 700mm long sample tube (PKT 3)Glass Expansion is ISO 9001:2015 certified by AB Certification, No. AU4501-9001